System | Description | Features | Image |
Particulate Removal Systems (PRS) | Return oil or fluids to their original state with this exclusive equipment designed for rapid removal of particulate contamination. | - Heaters with low watt density and low oil level float
- Fine fluid filtration from ISO 32 to ISO 680 heavy gear oils and sized to meet custom flow rates, temperatures, and viscosities
- Process and high limit thermocouples on separate controllers
- Achieve 99.9% efficiencies for low industry setting particle counts
- Variable Frequency Drive (VFD) in the control panel to manage speed
- Available in stainless steel for chemical flushes
| |
Vacuum Oil Purifier (VOP) / Vacuum Dehydrator Unit (VDU) | Increase oil longevity and maintain productivity on system components while removing free and emulsified water, dissolved gases, light hydrocarbons, solvents, and particulate contamination from lines, pipes and reservoirs during operation. | - Flow rates of 5 to 50 GPM and maximum pump pressure of 80 PSI
- Fitted with high efficiency micro-glass media filters with typical removal rates of > 99.9% for the rated particulate size
- Variable Frequency Drive (VFD) in the control panel to manage speed
- Explosion proof, NEMA 4 and NEMA 7 (HAZOP) rated skids available
- Window to monitor process oil level and gas transfer
- Overheat protection
| |
Fuel Coalescers (FCS) | When water and particulate contamination is removed from the fuel, the life of equipment is increased while machine downtime, operational costs, and maintenance workload are lowered substantially. | - Left filter element attracts water by cohesion force
- Right filter element repels water by non-cohesion force
- Water is drained by manual and automatic water sensing valves
- Can remove water in fuel oil from an emulsified state as low as 25 PPM
| |
Transformer Oil Purifier (TOP) | Increase the life of your transformer and decrease oil costs with a transformer oil purification system designed to remove dissolved gases, water, light hydrocarbons, and particulate contamination from dielectric fluids and transformer oils. | - Raises temperature to 150 degrees Fahrenheit and exposes oil to high surface area and -29” Hg or as low as 0.05 Torr within the vacuum chamber
- Flow rates of 5 to 30 GPM and operate on 480V at 30 to 120 amps with maximum pump pressure of 80 PSI
- Explosion proof, NEMA 4 and NEMA 7 (HAZOP) rated skids available
- Alarm lights and auto-shutdown when filters are plugged
| |
Varnish Absorption System (VAS) | Remove oxidation plated inside your turbine lube system, including bearings and servo valves both in operation or down. | - Uses a granular adsorbent resin and fitted with a high-efficiency micro-glass filter element to remove hard particulate contamination
- Flow rate of 10 GPM and operate on 120V with maximum pump pressure of 80 PSI
- Outfitted with both pre- and post-filter sample ports for quick non-intrusive sampling
- Explosion proof, NEMA 4 and NEMA 7 (HAZOP) rated skids available
- Fuse protected electrical system with alarm lights and auto-shutdown when filters are plugged
| |
Filter Housings | Conco has a range of filter vessels available for rental and purchase. | - Built from a selection of metals, including carbon steel, 304, and 316 Stainless Steel to increase corrosion resistance and eliminate the need for expensive coatings and oxidation within the filter vessels
- Provide sizing, design, and fabrication of custom ASME code and non-code filter housings
| |